CIP RC/PT Girder Help

Live Load & Combination Min/Max Stresses Report

Note: This report is identical for Pedestrian loadings.

The POI column shows the name or label of the POI and, for program-generated POIs, it is composed of a span number and a fractional distance into the span. For example, the POI labeled "Sp1.050" is for the POI at midspan in Span-1. User-specified POIs will appear here as well. The Location column shows the physical location of the POI on the box girder, relative to the start of the girder.

The first two Max and Min columns show the maximum and minimum stresses in the top of the box girder, and the second two Max and Min columns show the maximum and minimum stresses in the bottom of the box girder.